论文部分内容阅读
泸天化股份公司循环冷却水系统目前都采用的是电机驱动机械通风冷却塔。仅风机电机每年的电耗占循环水系统总运行电耗的30%~35%,特别是木结构的3#凉水塔,其管理和设备安全维护费用都很高。对3#凉水塔采用水动风机重新进行设计建造,每年可节约电费约300万元。公司的工业废水排放量也非常大,如果经过处理后作为循环冷却水系统的补水或作为一部分一次水使用,其经济效益也非常可观。
Lutianhua Co. circulating cooling water system are currently used motor-driven mechanical ventilation cooling tower. Only the annual power consumption of fan motor accounts for 30% ~ 35% of the total running power consumption of circulating water system, especially the 3 # cooling tower with wood structure, and its management and equipment safety and maintenance costs are very high. On the 3 # cooling towers using water fan to re-design and construction, annual savings of about 3000000 yuan. The company’s industrial wastewater discharge is also very large, if after treatment as a circulating cooling water system, or as part of a water reuse, its economic benefits are also very impressive.